An angle ISA 50 × 50 × 6 is connected to a gusset plate 5 mm thic

An angle ISA 50 × 50 × 6 is connected to a gusset plate 5 mm thic
| An angle ISA 50 × 50 × 6 is connected to a gusset plate 5 mm thick, with 16 mm bolts. What is the bearing strength of the bolt when the hole diameter is 16 mm and the allowable bearing stress is 250 MPa?

A. 8 kN

B. 20 kN

C. 22 kN

D. 24 kN

Please scroll down to see the correct answer and solution guide.

Right Answer is: B

SOLUTION

Concept:

The bearing strength of a single bolt is given as

Bearing Strength, FB = Permissible stress in bearing (fbp) × bearing area (Ab)

Bearing area, Ab = hole diameter × thickness (t)

Where ,

 t = minimum (Sum thickness of Covering plate / gusset plate thickness, thickness of main plate)

Calculation:

Given: fbp = 250 MPa, d = 16 mm;

Thickness of gusset plate = 5 mm and Thickness of main plate = 6 mm

t = 5 mm

Bearing Strength, FB = Permissible stress in bearing (fbp) × bearing area (Ab)

FB = 250 × 16 × 5 = 20,000 N

FB = 20 kN