A source V s = 200 cos ωt delivers power to a load at power facto

A source V s = 200 cos ωt delivers power to a load at power facto
| A source Vs = 200 cos ωt delivers power to a load at power factor 0.8 lag. The reactive power is 300 VAR. The Active Power is given by?

A. 200 Watts

B. 225 Watts

C. 400 watts

D. 300 Watts

Please scroll down to see the correct answer and solution guide.

Right Answer is: C

SOLUTION

Concept:

The power triangle is as shown below.

P = Active power (or) Real power in W = Vrms Irms cos ϕ

Q = Reactive power in VAR = Vrms Irms sin ϕ

S = Apparent power in VA = Vrms Irms

S = P + jQ

\(S = \sqrt {{P^2} + {Q^2}} \)

ϕ is the phase difference between the voltage and current

Power factor \(\cos \phi = \frac{P}{S}\)

Calculation:

Given that, power factor (cos ϕ) = 0.8

sin ϕ = 0.6

Reactive power (Q) = VI sin ϕ = 300 VAR

VI = 500 VA

⇒ Active power (P) = VI cos ϕ = 500 × 0.8 = 400 W